MIL-DTL-23599B(AS)
4.7.1 Temperature test. The rescue hook shall be tested thermally to temperatures ranging
from -50° F to +160° F in accordance with methods 501.5 and 502.5, Procedure 1, Storage of
MIL-STD-810.
4.7.2 Humidity test. The rescue hook shall undergo a humidity test in accordance with
method 507.5, Procedure I, Induced Cycles of MIL-STD-810.
4.7.3 Salt-fog test. The rescue hook shall undergo a salt-fog test with an alternating 24 hour
period of exposure and drying time, for a minimum of four 24 hour periods. This test will
determine the effect of a sea salt atmosphere on corrosion and physical function of the hooks.
Conduct the test in accordance with method 509.5 of MIL-STD-810.
4.7.4 Sand and dust. The rescue hook shall undergo a sand and dust test with six faces
exposed, in accordance with method 510.5, Procedure I, Dust and Procedure II, Sand of
MIL-STD-810.
5.
PACKAGING
5.1 Packaging. For acquisition purposes, the packaging requirements shall be as specified
in the contract or order (see 6.2). When packaging of materiel is to be performed by DoD or in-
house contractor personnel, these personnel need to contact the responsible packaging activity to
ascertain packaging requirements. Packaging requirements are maintained by the Inventory
Control Point's packaging activities within the Military Service or Defense Agency, or within the
military service's system commands. Packaging data retrieval is available from the managing
Military Department's or Defense Agency's automated packaging files, CD-ROM products, or
by contacting the responsible packaging activity.
6.
NOTES
(This section contains information of a general or explanatory nature that may be may be
helpful, but is not mandatory.)
6.1 Intended use. The rescue hook covered by this specification is used to assist personnel
performing hoist rescue work from aircraft.
6.2 Ordering data. Acquisition documents should specify the following:
a.
Title, number, and date of this specification.
b.
Quantity desired
c.
Drawings
d.
Whether first article inspection is waived (see 4.2).
e.
Packaging requirements (see 5.1).
f.
Name and address of the first article inspection laboratory (see 4.3.1).
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business